[1/29] SKB request to protect from lightening. How many KV test are FXN at surge test. And What point does test at Surge test [1/29] It will be discussed with HW engineer seperately. But it should be update here |
|
|
FXN's answer ------------------------------------------------- IEC standard :EN61000-4-5 Input voltage:+/-1kV Input point:AC power port Surge wave :1.2/50μs(CWG) |
|
|
agree on a test spec |
| Date Modified | Username | Field | Change |
|---|---|---|---|
| 2019-02-22 11:32 | (SW) Jacky Chiang | New Issue | |
| 2019-02-28 09:54 |
|
Assigned To | => (HW) Sean Chiang |
| 2019-02-28 09:54 |
|
Status | new => assigned |
| 2019-02-28 09:55 |
|
Note Added: 0001252 | |
| 2019-02-28 09:55 |
|
Note Added: 0001253 | |
| 2019-02-28 09:56 |
|
Note Edited: 0001253 | |
| 2019-02-28 09:56 |
|
Issue Monitored: (ALTech) SY Yoon | |
| 2019-02-28 09:56 |
|
Issue Monitored: (PM) Sheila Tu | |
| 2019-02-28 09:56 |
|
Issue Monitored: (ALTech) Eric Kim | |
| 2019-02-28 09:56 |
|
Issue Monitored: (ALTech) Jewoo Lee | |
| 2019-02-28 09:57 |
|
Issue Monitored: (ALTech) Philip | |
| 2019-03-05 21:19 |
|
Status | assigned => closed |
| 2019-03-05 21:19 |
|
Resolution | open => fixed |
| 2019-03-05 21:19 |
|
Note Added: 0001334 |